Optimization Strategies

Packaged Central Plants

 

Features and Flexibility for any Central Energy Plant

  • Standard industrial PLC platform guarantees reliability and long-term component availability. 

  • Field-proven core functional building blocks configured per system for maximum energy performance / minimum installation cost. 

  • Central Control Panel contains 

  • Operator touchscreen (door-mounted)

  • CPU executing adaptive algorithms

  • Local I/O, Hand-Off-Auto switches

  • Communication interfaces for Internet and/or BAS.

  • Field Control Panel option for large / distributed systems, 

  • Add remote operator displays where needed.

  • CAT 5E cable reduces remote I/O and  HOA wiring costs 

  • Independent operation from central panel for redundancy, reliability.

 

Operator Interface: Touch Screen Input and Graphical Display

Touch screen input and graphical displays created by experienced professionals provide an intuitive window into the process to help personnel keep the system running with minimum training.

Click here for a complete online system demonstration.

Operator Interface: Comprehensive Help System

Every Control and Energy Optimization (CEO) display unit contains all help documentation for your specific system... YES!! On The Display.  This includes a general operator display PDF file that details how to utilize the CEO and a System Specific Operation manual including all up-to-date drawings, sequences of operation and hardware cut-sheets.

Along with the above reference material there is a help page with the contact information for your tekWorx service personnel and Training Videos for many of the frequently needed items.

NOTE: The demonstration video to the right is reduced in size for this example.

Control System Features and Specifications

    Features:

  • Industrial PLC architecture
  • IEC-61131 compliant program code
  • Graphical operator display with integrated touchscreen.
  • Supports redundant CPU configuration
  • UL/CUL listed, approved for CE
  • Shock, vibration and RFI/EMI specs  per IEC directives
  • NEMA 12 sealed front panel.
  • 0 - 50°C @ 95% RH

    Input/Output Options:

  • Virtually Limitless Drops utilizing Standard Ethernet Networking
  • 64 modules/drop, 4 points/module
  • All analog and digital signal ranges

    Communications:

  • Integral Ethernet and serial ports.
  • Remote access to Internet/Intranet .
  • Open protocol support: Modbus, BACnet, and OPC
  • Proprietary BAS networks: JCI N2, call for others